Lenel LNL-M2220 Intelligent Dual Reader Controller, 2-Door
Description
Lenel LNL-M2220 Intelligent Dual Reader Controller for OnGuard
The Lenel LNL-M2220 Intelligent Dual Reader Controller is a single-board M-Series controller that runs one or two doors directly and connects to the OnGuard server over Ethernet. Its downstream RS-485 port adds up to 32 more devices for a maximum of 64 doors, so a one-door install can grow without replacing the panel. It stores 250,000 cardholders and 500,000 events, and supports ASSA ABLOY Aperio, Schlage AD400/Engage and SimonsVoss wireless locks.
Key Specifications
| Doors / readers | 1 or 2 doors on board; up to 64 doors with expansion |
| Cardholder capacity | 250,000 cardholders (selective download for larger databases) |
| Event buffer | 500,000 events |
| Card formats / access levels | 16 card formats; 32,000 access levels |
| Reader interface | 2 ports: TTL, F/2F or 2-wire RS-485 (OSDP, Secure Channel) |
| Reader power | 600 mA maximum each port |
| Downstream expansion | 1 RS-485 port, up to 32 devices |
| Host communication | Ethernet 10/100; optional secondary NIC via USB2-OTGE100 |
| Encryption | TLS 1.2/1.3 to OnGuard; AES-256 to Series 3 modules; data-at-rest option |
| Power input | 12 to 24 VDC ± 10%, 500 mA (plus reader current) |
| Inputs / outputs | 8 supervised inputs + tamper and UPS fault; 4 relays, 5 A NO / 3 A NC @ 30 VDC |
| Approvals | FCC Part 15, CE, RoHS, UL 294 |
Full specifications are listed in the Detailed Specifications tab.
Why Choose the Lenel LNL-M2220?
- Runs one or two doors on a single board
- Grows to 64 doors with downstream RS-485 modules
- 250,000 cardholders and a 500,000-event log on board
- Keeps local functions running if the OnGuard server connection is lost
- Secure 32-bit processor with TLS 1.2/1.3 to OnGuard
- OSDP readers with Secure Channel and biometric template support
- Wireless lock support for ASSA ABLOY Aperio, Schlage AD400/Engage and SimonsVoss
- Elevator control for up to 128 floors
Two Doors on One Board
Two on-board reader ports, eight supervised inputs and four relays give the LNL-M2220 everything needed for two doors with door contacts, request-to-exit devices and lock control, plus two dedicated inputs for cabinet tamper and UPS fault monitoring.
Readers and Credentials
Each reader port supports Data1/Data0 (Wiegand), Clock/Data, supervised and unsupervised F2F, biometric readers and bi-directional OSDP over RS-485, including OSDP biometric template transfer and Secure Channel encryption. Reader ports supply up to 600 mA each, and a jumper selects regulated 12 VDC or pass-through power.
Expansion to 64 Doors
The downstream RS-485 two-wire port connects up to 32 LenelS2 devices, such as LNL-1300 and LNL-1320 reader interface modules and LNL-1100 and LNL-1200 I/O modules, for a maximum of 64 doors from one controller.
Capacity and Local Operation
Up to 250,000 cardholders are stored in 6 MB of flash, with selective download for larger databases, and 500,000 events are kept in super-capacitor-backed memory. The controller supports 16 card formats, 32,000 access levels and elevator control for up to 128 floors, and nearly all local functions continue if the server connection is lost.
Cybersecurity
A secure 32-bit processor, TLS 1.2/1.3 to OnGuard, AES-256 to LenelS2 Series 3 modules (AES-128 for Series 2), an optional data-at-rest encryption setting and background firmware download.
Typical Applications
- Building entrances with in and out readers
- Two-door suites, labs and offices
- Sites that start small and add doors later
- Wireless lock deployments with Aperio, Schlage or SimonsVoss
- Elevator access control
Compatible Accessories
Compatible accessories for the Lenel LNL-M2220. Linked items are available at Affinitech Store; contact us for the others:
- Lenel LNL-1300-S3 Series 3 Single Reader Interface Module
- Lenel LNL-1320-S3 Series 3 Dual Reader Interface Module
- Lenel LNL-1100-S3 Series 3 Input Control Module
- Lenel LNL-1200-S3 Series 3 Output Control Module
- USB2-OTGE100 USB-to-Ethernet adapter (secondary NIC)
- BR2330 or CR2330 3V lithium battery (optional)
Compare Lenel OnGuard Intelligent Controllers
| Model | Doors | Type | Best for |
|---|---|---|---|
| Lenel LNL-M2210 | 1 door (1-2 readers) | PoE single door controller | Single doors and remote doors on one network cable |
| Lenel LNL-M2220 (this controller) | 2 on board, up to 64 | Dual reader controller | Entrances and 1-2 door sites that will grow |
| Lenel LNL-M3300 | Up to 64 via modules | System controller (no reader ports) | Multi-door panels built from LNL-1300/1320 modules |
| Lenel LNL-M4420 | 2 on board, up to 64 | Advanced dual reader controller, BACnet | Enterprise sites, 1,000,000+ cardholders, BACnet |
| Lenel LNL-X2210 | 1 door (1-2 readers) | PoE single door controller (X-Series) | Existing X-Series systems; replaced by LNL-M2210 |
| Lenel LNL-X2220 | 2 on board, up to 64 | Dual reader controller (X-Series) | Existing X-Series systems; replaced by LNL-M2220 |
| Lenel LNL-X3300 | Up to 64 via modules | System controller (X-Series) | Existing X-Series systems; replaced by LNL-M3300 |
| Lenel LNL-X4420 | 2 on board, up to 64 | Advanced dual reader controller (X-Series) | Existing X-Series systems; replaced by LNL-M4420 |
Matching an existing X-Series system? See the Lenel LNL-X2220.
Explore More
Frequently Asked Questions
How many doors can the Lenel LNL-M2220 control?
One or two doors on board. Its downstream RS-485 port connects up to 32 more devices for a maximum of 64 doors.
How many cardholders and events does it store?
Up to 250,000 cardholders in 6 MB of flash, with selective download for larger databases, and 500,000 events.
What power does the LNL-M2220 need?
12 to 24 VDC ± 10%, 500 mA maximum, plus up to 600 mA for each reader port. It is not a PoE controller.
Which readers are supported?
Data1/Data0 (Wiegand), Clock/Data, supervised and unsupervised F2F, biometric readers and OSDP RS-485 readers and keypads, including OSDP Secure Channel.
Does it support wireless locks?
Yes. The datasheet lists ASSA ABLOY Aperio, Schlage AD400, Schlage Engage and SimonsVoss.
How is communication secured?
TLS 1.2/1.3 to OnGuard, AES-256 to Series 3 modules (AES-128 for Series 2), plus an optional data-at-rest encryption setting.
What happens if the network goes down?
Nearly all local functions continue until the connection to the OnGuard server is restored.
How are memory and the clock backed up?
A super capacitor backs memory and the clock for 10 days. An optional 3V BR2330 or CR2330 lithium battery can be field installed.
Which OnGuard versions support M-Series controllers?
LenelS2 states that M-Series controllers are not supported on OnGuard 7.4 or lower, and OnGuard 8.3 adds native M-Series support. Contact us to confirm your version.
What approvals does the LNL-M2220 carry?
FCC Part 15, CE, RoHS and UL 294.
Detailed Specifications
Lenel LNL-M2220 Specifications
| Specification | Details |
|---|---|
| System Capacity | |
| Cardholders | 250,000 (6 MB flash; selective download for larger databases) |
| Event buffer | 500,000 events, super-capacitor backed |
| Downstream devices | Up to 32 devices (64 doors maximum) |
| Card formats | 16 |
| Access levels | 32,000 |
| Elevator control | Up to 128 floors |
| Wireless locks | ASSA ABLOY Aperio, Schlage AD400, Schlage Engage, SimonsVoss |
| Encryption | TLS 1.2/1.3 to OnGuard; AES-256 to Series 3 modules (AES-128 to Series 2); data-at-rest option |
| General | |
| Primary Power | 12 to 24 VDC ± 10%, 500 mA maximum (reader current not included) |
| Reader Ports | 600 mA maximum each (add up to 600 mA to primary power current each) |
| Primary Host Communication | Ethernet: 10-BaseT/100Base-TX |
| Secondary Host Communication | USB port (2.0) with optional adapter: pluggable model USB2-OTGE100 |
| Serial I/O Device | One each: 2-wire RS-485, 2,400 to 115,200 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and 1 stop bit |
| Inputs | Eight unsupervised / supervised, standard EOL: 1k/1k ohm, 1% 1/4 watt; two unsupervised inputs dedicated for cabinet tamper and UPS fault monitoring |
| Outputs | Four relays: Normally open contact (NO): 5 A @ 30 VDC resistive; Normally closed contact (NC): 3 A @ 30 VDC resistive |
| Battery | Memory/Clock backup: Super Capacitor (10 days). Optional, 3V Lithium, type BR2330 or CR2330 (battery not included, field installable). |
| Reader Interface | |
| Power (Jumper selectable) | 12 VDC ± 10% regulated, 600 mA maximum each reader (input voltage [VIN] must be greater than 17 VDC) or 12 to 24 VDC ± 10% (input voltage passed through), 600 mA maximum each reader |
| Data Inputs | TTL compatible, F/2F or 2-wire RS-485 |
| RS-485 Mode | 9,600 to 115,200 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and 1 stop bit. Maximum cable length: 2,000 ft. (609.6m) |
| LED Output | TTL levels, high > 3 V, low < 0.5 V, 5 mA source/sink maximum |
| Buzzer Output | Open collector, 12 VDC open circuit maximum, 40 mA sink maximum |
| Cable Requirements | |
| Power and Relays | One twisted pair, 18 to 16 AWG |
| Ethernet | CAT-5, minimum |
| TTL Reader | 18 AWG, depending on length and requirements |
| Alarm Input | One twisted pair, 30 ohms maximum, typically 22 AWG @ 1,000 ft. (304.8m) |
| RS-485 I/O Device Port | One twisted pair with drain wire and shield, 120 ohm impedance, 24 AWG, 4,000 ft. (1,219m) maximum |
| RS-485 Reader Port | One twisted pair with drain wire and shield, 120 ohm impedance, 24 AWG, 2,000 ft. (610m) maximum |
| Mechanical | |
| Dimensions | 8.0 W x 6.0 L x 1.0 H in. (203.2 x 152.4 x 25mm) |
| Weight | 9.0 oz. (255g) nominal, board only |
| Environmental | |
| Temperature | -55° to +85° C, storage; 0° to +70° C, operating |
| Humidity | 5 to 95% RHNC |
| Heat Output (BTUs) | at 12 VDC, 20.5 BTU/hr; at 24 VDC, 22.9 BTU/hr |
| Approvals | FCC Part 15, CE, RoHS, UL 294 |
| Notes | |
| Class 2 | The interface is for use in low voltage, Class 2 Circuits only. |
| Codes | The installation of this device must comply with all local fire and electrical codes. |
| Disclaimer | Specifications subject to change without notice. |