Lenel LNL-X4420 Advanced Dual Reader Controller with BACnet

Brand: LenelS2
SKU:
LNL-X4420
(No reviews yet) Write a Review
Contact us for a Quote Today!
Price: $4,942.00
delivery-sp
Free Ground Shipping
Lenel Authorized Dealer
Five to Seven Business Days Typical Leadtime
5-7 Day Typical Lead Time

Description

Newer model available: The Lenel LNL-X4420 has been succeeded by the Lenel LNL-M4420, which stores 500,000 events, supplies up to 600 mA per reader port and communicates with OnGuard over TLS 1.2/1.3. Shop the Lenel LNL-M4420 at Affinitech Store.

Lenel LNL-X4420 Advanced Dual Reader Controller for OnGuard

The Lenel LNL-X4420 Advanced Dual Reader Controller is the highest-capacity X-Series controller for OnGuard. It runs two doors on board, connects up to 64 devices (64 doors) on two downstream RS-485 ports, stores more than 1,000,000 cardholders depending on configuration and keeps 50,000 events. It exchanges up to 63 BACnet points with building automation systems.

Key Specifications

Doors / readers2 on-board reader ports; up to 64 doors with expansion
Cardholder capacityMore than 1,000,000 (depending on configuration)
Event buffer50,000 events, battery-backed
Card formats / access levels16 card formats; 32,000 access levels (255 per badge)
Reader interfaceWiegand, magnetic stripe, Clock/Data, F2F, OSDP RS-485 with Secure Channel
Reader power300 mA maximum each reader
Downstream expansion2 RS-485 ports, up to 64 devices
Building integrationBACnet, up to 63 points
EncryptionAES128 or TLS 1.2 to OnGuard; AES-256 to Series 3 modules
Power input12 to 24 VDC ± 10%, 550 mA (plus reader current)
Inputs / outputs8 supervised inputs + tamper and UPS fault; 4 Form-C relays, 5 A NO / 3 A NC @ 30 VDC
ApprovalsFCC Part 15, CE, RoHS, UL 294, UL 2610

Full specifications are listed in the Detailed Specifications tab.

Why Choose the Lenel LNL-X4420?

  • More than 1,000,000 cardholders, depending on configuration
  • Two doors on board and up to 64 devices on two RS-485 ports
  • BACnet interface with up to 63 points
  • OSDP Secure Channel and AES-256 to Series 3 modules
  • Optional onboard FIPS-201 authentication with HID pivCLASS or EntryPoint
  • UL 294 and UL 2610 listed

Enterprise Capacity

The LNL-X4420 stores more than 1,000,000 cardholders in 16 to 96 MB of flash, depending on configuration, and keeps 50,000 events in battery-backed memory. It supports 16 card formats, 32,000 access levels (255 per badge) and elevator control for up to 128 floors.

Two Doors On Board, 64 Doors in Total

Two reader ports, eight supervised inputs and four Form-C relays run two doors directly, and two downstream RS-485 ports add up to 64 devices, including LNL-1100, LNL-1200, LNL-1300 and LNL-1320 modules, Schlage PIM-400 interfaces (OnGuard 7.5 and higher) and ASSA ABLOY Aperio devices.

BACnet Building Integration

Up to 63 BACnet points can be defined through OnGuard as a mix of physical inputs and virtual outputs, giving two-way state exchange with building control systems.

Cybersecurity and Credentials

AES128 or TLS 1.2 (with AES256) to OnGuard, AES-256 to Series 3 modules (AES-128 for Series 2), OSDP Secure Channel and an optional data-at-rest encryption setting, plus optional onboard FIPS-201 authentication with HID pivCLASS or Technology Industries EntryPoint.

Typical Applications

  • Adding controllers to an existing X-Series OnGuard system
  • Like-for-like replacement of an LNL-X4420
  • Enterprise and campus panels with up to 64 doors
  • BACnet building integration

Compatible Accessories

Compatible accessories for the Lenel LNL-X4420. Linked items are available at Affinitech Store; contact us for the others:

Compare Lenel OnGuard Intelligent Controllers

ModelDoorsTypeBest for
Lenel LNL-M22101 door (1-2 readers)PoE single door controllerSingle doors and remote doors on one network cable
Lenel LNL-M22202 on board, up to 64Dual reader controllerEntrances and 1-2 door sites that will grow
Lenel LNL-M3300Up to 64 via modulesSystem controller (no reader ports)Multi-door panels built from LNL-1300/1320 modules
Lenel LNL-M44202 on board, up to 64Advanced dual reader controller, BACnetEnterprise sites, 1,000,000+ cardholders, BACnet
Lenel LNL-X22101 door (1-2 readers)PoE single door controller (X-Series)Existing X-Series systems; replaced by LNL-M2210
Lenel LNL-X22202 on board, up to 64Dual reader controller (X-Series)Existing X-Series systems; replaced by LNL-M2220
Lenel LNL-X3300Up to 64 via modulesSystem controller (X-Series)Existing X-Series systems; replaced by LNL-M3300
Lenel LNL-X4420 (this controller)2 on board, up to 64Advanced dual reader controller (X-Series)Existing X-Series systems; replaced by LNL-M4420

Building a new system? See the Lenel LNL-M4420, the current M-Series version.

Explore More

Frequently Asked Questions

Is the LNL-X4420 still in production?

LenelS2 announced end of production for the Mercury X-Series controllers in 2024 and introduced the M-Series. The LNL-M4420 is the M-Series advanced dual reader controller.

How many cardholders does the Lenel LNL-X4420 store?

More than 1,000,000 cardholders, depending on configuration.

How many doors can it control?

Two doors on its own reader ports and up to 64 devices (64 doors) on two downstream RS-485 ports.

Does the LNL-X4420 support BACnet?

Yes. Up to 63 BACnet points can be defined through OnGuard.

How many events does it store?

50,000 events in battery-backed, non-volatile memory.

What power does it need?

12 to 24 VDC ± 10%, 550 mA maximum, plus reader current.

How is communication secured?

AES128 or TLS 1.2 (with AES256) to OnGuard, AES-256 to Series 3 modules and OSDP Secure Channel.

What approvals does the LNL-X4420 carry?

FCC Part 15, CE, RoHS, UL 294 and UL 2610.

View AllClose

Detailed Specifications

Lenel LNL-X4420 Specifications

SpecificationDetails
System Capacity
CardholdersMore than 1,000,000 (depending on configuration); 16-96 MB flash
Event buffer50,000 events, battery-backed
Downstream devicesUp to 64 devices (64 doors) on two RS-485 ports
BACnetUp to 63 points
Card formats16
Access levels32,000 (255 per badge)
Elevator controlUp to 128 floors
WirelessSchlage PIM-400 (OnGuard 7.5 and higher), ASSA ABLOY Aperio
FIPS-201Optional onboard HID pivCLASS or Technology Industries EntryPoint embedded authentication
EncryptionAES128 or TLS 1.2 (with AES256) to OnGuard; AES-256 to Series 3 modules (AES-128 to Series 2); OSDP Secure Channel; data-at-rest option
General
Primary Power12 to 24 VDC ± 10%, 550 mA maximum (reader current not included)
Reader Ports600 mA maximum (add 600 mA to primary power current)
Primary Host CommunicationEthernet: 10-BaseT/100Base-TX
Secondary Host CommunicationUSB port (2.0) with optional adapter: pluggable model USB2-OTGE100
SIO CommunicationsTwo each: 2-wire RS-485, 2,400 to 115,200 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and 1 stop bit
InputsEight unsupervised / supervised, standard EOL: 1k/1k ohm, 1% 1/4 watt; two dedicated for tamper and UPS fault monitoring
OutputsFour relays, Form-C with dry contacts: Normally open contact (NO): 5 A @ 30 VDC resistive; Normally closed contact (NC): 3 A @ 30 VDC resistive
Reader Interface
Power12 VDC ± 10% regulated, 300 mA maximum each reader (input voltage [VIN] must be greater than 20 VDC) or 12 to 24 VDC ± 10% (input voltage passed through), 300 mA maximum each reader
Data InputsTTL compatible inputs, magnetic stripe and Wiegand standards supported. Maximum cable length: 500 ft. (152m)
RS-485 Mode9,600 to 115,200 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and 1 stop bit. Maximum cable length: 2,000 ft. (609.6m)
LED OutputTTL levels, high > 3 V, low < 0.5 V, 5 mA source/sink maximum
Buzzer OutputTTL levels, high > 3 V, low < 0.5 V, Low = Active, 5 mA source/sink maximum
Cable Requirements
Power and RelaysOne twisted pair, 18 to 16 AWG
EthernetCAT-5, minimum
TTL Reader22 to 16 AWG, depending on length and requirements
Alarm InputOne twisted pair, 30 ohms maximum, typically 22 AWG @ 1,000 ft. (304.8m)
RS-485 I/O Device PortOne twisted pair with drain wire and shield, 120 ohm impedance, 24 AWG, 4,000 ft. (1,219m) maximum
RS-485 Reader PortOne twisted pair with drain wire and shield, 120 ohm impedance, 24 AWG, 2,000 ft. (610m) maximum
Mechanical
Dimensions8.0 W x 6.0 L x 1.0 H in. (203.2 x 152.4 x 25mm)
Weight10.65 oz. (302g) nominal
Environmental
Temperature-55° to +85° C, storage; 0° to +70° C, operating
Humidity5 to 95% RHNC
Heat Output (BTUs)at 12 VDC, 22.5 BTU/hr; at 24 VDC, 24.6 BTU/hr
Approvals
ApprovalsFCC Part 15, CE, RoHS, UL 294, UL 2610
View AllClose

Additional Information

FivetoSeven:
5-7 Day Typical Lead Time
View AllClose