AXIS XC1311 Explosion-Protected Network Horn Speaker – Class I Div 1 / Zone 1 Certified

The AXIS XC1311 is an explosion-protected network horn speaker certified worldwide for hazardous locations, delivering over 110 dB of clear voice to personnel in Class I Division 1, Zone 1 and Zone 21 areas. A re-entrant horn with compression driver, 7 W Class D amplifier and pre-configured DSP make it a complete audio system on a single PoE cable, with AXIS Audio Manager Edge built in. Its IP66/IP67 and NEMA 4X aluminum enclosure operates from -40 °C to 60 °C, suiting oil and gas, chemical, mining and processing sites.

Key Specifications

Speaker type Re-entrant horn with compression driver
Max sound pressure level >110 dB at 1 m
Frequency response 400 Hz - 5.5 kHz
Coverage pattern 54°
Amplifier Built-in 7 W Class D
Hazardous area (cULus) Class I Div 1 Groups A, B, C, D T5; Class I Zone 1 AEx db IIC T5 Gb; Zone 21 AEx tb IIIC T91°C Db
ATEX / IECEx Ex db IIC T5 Gb; Ex tb IIIC T91°C Db
Power PoE IEEE 802.3af/802.3at Type 1 Class 3 (typical 7 W, max 12.95 W)
Enclosure Impact-resistant aluminum, IP66/IP67, NEMA 4X, RAL 3000
Operating temperature -40 °C to 60 °C (-40 °F to 140 °F)
Weight 4220 g (9.3 lb)

Full specifications are listed in the Detailed Specifications tab.

Why Choose the AXIS XC1311?

  • Certified for gas (Class I Div 1, Zone 1 IIC) and dust (Zone 21 IIIC) areas
  • ATEX, IECEx, cULus, INMETRO, JPEx and more worldwide markings
  • Over 110 dB of focused voice for noisy industrial environments
  • All-in-one: amplifier, DSP and audio management on the device
  • Single PoE cable for power and network, no separate audio network
  • Remote health testing and event-triggered pre-recorded messages
  • Included bracket for wall or ceiling mounting
  • TAA compliant supply chain and Axis Edge Vault cybersecurity

Built for Hazardous Locations

The XC1311 carries flameproof (Ex db) and dust ignition protection by enclosure (Ex tb) certification, with ATEX II 2 G / II 2 D, IECEx and cULus Class I Div 1 markings, so it can be installed in potentially combustible gas and dust atmospheres. The red RAL 3000 aluminum housing is IP66, IP67 and NEMA 4X rated and handles condensing humidity from -40 °C to 60 °C.

Clear Messages Over Industrial Noise

A re-entrant horn with compression driver concentrates over 110 dB into a 54° pattern, and the built-in DSP keeps speech intelligible over long distances and loud machinery. Play scheduled safety announcements, let a camera with analytics trigger a pre-recorded warning when it detects smoke or missing protective equipment, or have an operator speak live to the scene.

Smart, Stand-Alone Network Audio

The speaker connects to a standard IP network and needs no extra hardware or software. AXIS Audio Manager Edge comes preinstalled for zones, content priority and user permissions, and remote health testing confirms it works without a trip into the hazardous area. It integrates with AXIS Camera Station, partner VMS, SIP telephony and mass notification systems such as Singlewire InformaCast and Alertus.

Installation

The included bracket supports wall and ceiling mounting, and the housing has two M20 and one 1/2-inch NPT cable side entries. Pair it with the AXIS Ex Connection Rail 8-port PoE++ for power and connectivity and the AXIS TQ1301-E Pole Mount or Pole Mount ExCam XF for poles. Installation must follow the certificate conditions and local hazardous-area codes.

Typical Applications

  • Oil and gas facilities and refineries
  • Chemical and pharmaceutical plants
  • Grain handling, food and dust-prone processing
  • Mining and wastewater treatment
  • Fuel depots and marine terminals

Compatible Accessories

Compatible accessories for the AXIS XC1311, available at Affinitech Store:

Compare AXIS Network Speakers

ModelKey specTypeBest for
AXIS C1310-E Mk II Over 121 dB max SPL Outdoor horn speaker, IP66 Perimeters, parking lots, yards
AXIS C1410 Mk II 90 dB max SPL, PIR sensor Indoor mini speaker Corridors, small rooms, offices
AXIS C1610-VE IK11 vandal rating Outdoor sound projector Vandal-prone outdoor areas
AXIS C1210-E Voice and background music Recessed ceiling speaker Classrooms, retail, lobbies
AXIS C1211-E Voice announcements Compact recessed ceiling speaker Offices, hallways, small rooms
AXIS C1510 Larger pendant model Pendant speaker High ceilings, warehouses, gyms
AXIS C1511 Compact pendant model Pendant speaker High ceilings in shops and lobbies
AXIS C1110-E Rich bass, full duplex Wall, ceiling or pole cabinet speaker Background music and voice
AXIS C1111-E Compact, IP55 casing Wall, ceiling or pole cabinet speaker Voice and music in smaller spaces
AXIS C1710 Speaker, LCD display and strobe Network display speaker Visual plus audible alerts
AXIS C1720 Two speakers and displays, strobe Corridor display speaker Hallways and corridors
AXIS XC1311 (this speaker) Class I Div 1 / Zone 1 certified Explosion-protected horn speaker Hazardous industrial areas

Explore More

Frequently Asked Questions About AXIS XC1311

Where can the AXIS XC1311 be installed?

In hazardous gas areas Class I Div 1 (Groups A, B, C, D), Class I Zone 1 IIC and Zone 1 IIC, and dust areas Zone 21 IIIC, as certified worldwide.

What are its ATEX and IECEx markings?

ATEX: II 2 G Ex db IIC T5 Gb and II 2 D Ex tb IIIC T91°C Db. IECEx: Ex db IIC T5 Gb and Ex tb IIIC T91°C Db.

How loud is it?

Over 110 dB at 1 m, with a frequency response of 400 Hz to 5.5 kHz and a 54° coverage pattern.

How is it powered?

By PoE IEEE 802.3af/802.3at Type 1 Class 3, typical 7 W and max 12.95 W.

What temperatures can it handle?

-40 °C to 60 °C (-40 °F to 140 °F) at 10-100% RH, condensing.

Does it need separate amplifiers or software?

No. The amplifier, DSP and AXIS Audio Manager Edge are built in, so it works as a stand-alone audio system.

Can it play pre-recorded messages from camera events?

Yes. Event rules can play audio clips, for example when a camera with analytics detects smoke or missing PPE.

Does it support SIP?

Yes. It supports SIP and is verified with SIP clients such as 2N, Yealink and Cisco and PBX servers such as Cisco Call Manager and Avaya.

What cable entries does it have?

Two M20 side entries and one 1/2-inch NPT side entry.

Is it TAA compliant?

Yes. The Axis datasheet lists the supply chain as TAA compliant.

What warranty does it have?

A 5-year Axis warranty.

View AllClose

Detailed Specifications

AXIS XC1311 Specifications

SpecificationDetails
Audio Hardware
EnclosureRe-entrant horn loudspeaker with compression driver
Max sound pressure level>110 dB at 1 m distance
Frequency response400 Hz - 5.5 kHz
Coverage pattern54°
Input/outputBuilt-in speaker
AmplifierBuilt-in 7 W Class D amplifier
Digital signal processingBuilt-in and pre-configured
Audio managementAXIS Audio Manager Edge built in: zone management (up to 200 speakers in 20 zones), content management for music and live/pre-recorded announcements, scheduling, content prioritization, health monitoring, user management. AXIS Audio Manager Pro for larger and more advanced systems (sold separately). AXIS Audio Manager Center cloud service for remote access and management of multi-site systems
Audio Software
Audio streamingOne-way
Audio encodingAAC LC 8/16/32/48 kHz, G.711 PCM 8 kHz, G.726 ADPCM 8 kHz, Axis µ-law 16 kHz, WAV, MP3 in mono/stereo from 64 kbps to 320 kbps; constant and variable bit rate; sampling rate 8 kHz to 48 kHz
System Integration
Application Programming InterfaceOpen API for software integration, including VAPIX; one-click cloud connection
Video management systemsAXIS Camera Station Edge, AXIS Camera Station Pro, AXIS Camera Station 5 and partner VMS software
Mass notificationSinglewire InformaCast, Intrado Revolution, Lynx, Alertus
Unified communication, SIP clients (verified)2N, Yealink, Cisco, Linphone, Grandstream
Unified communication, PBX/SIP servers (verified)Cisco Call Manager, Cisco BroadWorks, Avaya, Asterisk, Grandstream
Unified communication, cloud service providers (verified)Webex, Zoom
Supported SIP featuresSecondary SIP server, IPv6, SRTP, SIPS, SIP TLS, DTMF (RFC 2976 and RFC 2833), NAT (ICE, STUN, TURN)
RFC 3261 methodsINVITE, CANCEL, BYE, REGISTER, OPTIONS, INFO
DTMFRFC 4733 / RFC 2833
Event conditionsAudio: audio clip playing, audio detection, speaker test result; Call: state, state change; Device status: IP address blocked/removed, live stream active, network lost, new IP address, system ready; Edge storage: recording ongoing, storage disruption, storage health issues detected; I/O: digital input, manual trigger, virtual input; MQTT: subscribe; Scheduled and recurring: schedule
Event actionsAudio: run automatic speaker test; Audio clips: play, stop; I/O: toggle I/O once, toggle I/O while the rule is active; LEDs: flash status LED, flash status LED while the rule is active; Light and siren: run light profile, run light profile while the rule is active, stop activities; MQTT: publish; Notification: HTTP, HTTPS, TCP and email; Recordings: record audio, record audio while the rule is active; Security: erase configuration; SNMP traps: send, send while the rule is active
Built-in installation aidsTest tone verification and identification
Functional monitoringAuto speaker test
Approvals
Supply chainTAA compliant
EMCEN 55035, EN 55032 Class A, EN 61000-6-1, EN 61000-6-2; Australia/New Zealand: RCM AS/NZS CISPR 32 Class A; Canada: ICES(A)/NMB(A); Japan: VCCI Class A; USA: FCC Part 15 Subpart B Class A
SafetyCAN/CSA C22.2 No. 62368-1 ed. 3, IEC/EN/UL 62368-1 ed. 3
EnvironmentIEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14, IEC 60068-2-27, IEC 60068-2-78, IEC/EN 60529 IP66/IP67, NEMA 250 Type 4X
NetworkNIST SP500-267
CybersecurityETSI EN 303 645, BSI IT Security Label, FIPS-140
ExplosionCSA C22.2 No. 60079-0, CSA C22.2 No. 60079-1, CSA C22.2 No. 60079-31, IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-31, UL1203, UL 60079-0, UL 60079-1, UL 60079-31
Hazardous Area Certifications
ATEXII 2 G Ex db IIC T5 Gb; II 2 D Ex tb IIIC T91°C Db (certificate UL 24 ATEX 3177X)
IECExEx db IIC T5 Gb; Ex tb IIIC T91°C Db (certificate ULD 24.0006X)
cULusClass I Div 1 Groups A, B, C, D T5; Class I Zone 1 AEx db IIC T5 Gb; Zone 21 AEx tb IIIC T91°C Db (certificate E538733)
INMETROEx db IIC T5 Gb; Ex tb IIIC T91°C Db (certificate IEx 24.0202X)
IAEx db IIC T5 Gb; Ex tb IIIC T91°C Db (certificate MASC S/24-8423X)
OSHA TaiwanEx db IIC T5 Gb; Ex tb IIIC T91°C Db (certificate TD050170)
PESOEx db IIC T5 Gb (certificate P620272/1)
JPExEx db IIC T5 Gb; Ex tb IIIC T91°C Db (certificate DEK25.0023X)
Network
Network protocolsIPv4/v6, HTTP, HTTPS, SSL/TLS, QoS Layer 3 DiffServ, FTP, SFTP, CIFS/SMB, SMTP, Bonjour, UPnP, SNMP v1/v2c/v3 (MIB-II), DNS, DynDNS, NTP, PTP, RTSP, RTP, TCP, UDP, IGMPv1/v2/v3, RTCP, ICMP, DHCP, ARP, SOCKS, SSH, NTCIP, SIP
Cybersecurity
Edge securitySoftware: Signed firmware, brute force delay protection, digest authentication and OAuth 2.0 RFC6749 Client Credential Flow/OpenID Authorization Code Flow for centralized ADFS account management, password protection, Axis Cryptographic Module (FIPS 140-2 level 1). Hardware: Axis Edge Vault cybersecurity platform, secure element (CC EAL 6+), Axis device ID, secure keystore, secure boot
Network securityIEEE 802.1X (EAP-TLS, PEAP-MSCHAPv2), IEEE 802.1AR, HTTPS/HSTS, TLS v1.2/v1.3, Network Time Security (NTS), X.509 certificate PKI, host-based firewall
DocumentationAXIS OS Hardening Guide, Axis Vulnerability Management Policy, Axis Security Development Model, AXIS OS Software Bill of Material (SBOM)
General
System on chip (SoC)NXP i.MX 8M Nano
Memory1024 MB RAM, 1024 MB Flash
CasingIP66-, IP67- and NEMA 4X-rated; impact-resistant aluminum
ColorRAL 3000
Cable entries2x M20 cable side entries; 1x 1/2-inch NPT cable side entry
PowerPower over Ethernet (PoE) IEEE 802.3af/802.3at Type 1 Class 3; typical 7 W, max 12.95 W
ConnectorsNetwork: RJ45 10BASE-T/100BASE-TX PoE
ReliabilityDesigned for 24/7 operation
Operating conditions-40 °C to 60 °C (-40 °F to 140 °F); humidity 10-100% RH (condensing)
Storage conditions-40 °C to 65 °C (-40 °F to 149 °F); humidity 5-95% RH (non-condensing)
LanguagesEnglish, German, French, Spanish, Italian, Russian, Simplified Chinese, Japanese, Korean, Portuguese, Polish, Traditional Chinese, Dutch, Czech, Swedish, Finnish, Turkish, Thai, Vietnamese
Weight
Weight4220 g (9.3 lb)
Box Content
Box contentHorn speaker, installation guide, terminal block connector, ring terminal, owner authentication key
Optional Accessories
Optional accessoriesPole Mount ExCam XF, Pole Mount ExCam XPT
Sustainability
Substance controlPVC free; RoHS in accordance with EU RoHS Directive 2011/65/EU and EN 63000:2018; REACH in accordance with (EC) No 1907/2006
MaterialsScreened for conflict minerals in accordance with OECD guidelines
Warranty
Warranty5-year warranty