AXIS TA1203 250 W 120 V AC Power Enclosure, 03339-004
Description
AXIS TA1203 250 W 120 V AC Power Enclosure for A1810-B
The AXIS TA1203 Enclosure with Power Unit is a preassembled, lockable steel enclosure with a 250 W power supply and battery charger for AXIS A1810-B eight-door access control systems. This is the US 120 V AC version without the fire alarm interface. The backup battery is not included.
Key Specifications
| Part number | 03339-004 |
| Type | Enclosure with 250 W power unit |
| Compatible with | AXIS A1810-B Network Door Controller, AXIS TA1101-B converters |
| Power supply | 250 W (LifeSafety Power FPO250) |
| AC input | 120/230 V AC +10%/-15%, 50-60 Hz, 3.2 A (this SKU: US 120 V AC version) |
| DC output (12 V jumper) | 11.3-12.0 V, max 20 A (18 A while charging) |
| Battery | Not included; SLA, gel cell or LiFePO4, up to 80 Ah |
| Operating temperature | 0 to 49 °C (32 to 120 °F) |
| Casing | Steel, white (NCS S 1002-B) |
| Weight | 120 V AC: 13.8 kg (30.5 lb) |
| Shipping weight | 39.73 lb |
Full specifications are listed in the Detailed Specifications tab.
Compatible Products
Compatible AXIS products available at Affinitech Store:
Related Products
Related AXIS accessories, available at Affinitech Store:
- AXIS TA1203 250 W Power Enclosure with FAI
- AXIS TA1202 150 W 120 V AC Power Enclosure
- AXIS TA1101-B Wiegand to OSDP Converter
- AXIS TA1201 Wall Mount Enclosure for TA1101-B
Explore More
- See the full Access Control collection
- Browse all Power Supplies at Affinitech Store
- Shop more AXIS products at Affinitech Store
Frequently Asked Questions About AXIS TA1203
What is the AXIS TA1203?
A ready-to-install steel enclosure with a built-in 250 W power unit, battery charger and tamper switch, built around the AXIS A1810-B Network Door Controller for eight-door systems.
How does this version differ from the FAI version?
This one has no fire alarm interface. The AXIS TA1203 with FAI (03341-004) adds the fire alarm interface and is a 120 V AC version.
Is a backup battery included?
No. It supports sealed lead acid, gel cell or lithium iron phosphate batteries up to 80 Ah.
How is it different from the TA1202?
The TA1203 has a 250 W power unit for the AXIS A1810-B (eight doors), while the TA1202 has a 150 W unit for the AXIS A1710-B (four doors).
What is the AC input?
120/230 V AC at 50-60 Hz. This US SKU is the 120 V AC version according to Axis product data.
Detailed Specifications
AXIS TA1203 Specifications
| Specification | Details |
|---|---|
| Product | |
| Model | AXIS TA1203 |
| Part number | 03339-004 |
| Variants | |
| Variant 1 | AXIS TA1203 Enclosure with Power unit, 120 V AC or 230 V AC (this SKU: US 120 V AC) |
| Variant 2 | AXIS TA1203 Enclosure with Power unit and FAI, 120 V AC |
| Power | |
| Input | 120/230 V AC +10%/-15% at 50-60 Hz, 3.2 A |
| Output, FPO jumper set to 12 V | 11.3-12.0 V, max 20 A (18 A while battery is charging) |
| DC1 output | Continuous |
| DC2 output | Switched on FAI input |
| Protection | Overload and short-circuit protection with auto-restart |
| Battery | |
| Backup battery | Not included; supports SLA, Gel Cell, or Lithium Iron Phosphate |
| Max battery size | 80 Ah |
| Max charge current | 2 A |
| Fuse rating | ATM 30 A |
| Charger | Built-in microprocessor-controlled smart charger |
| Switchover | Automatic switchover to backup battery with zero transfer time |
| Low battery cutoff | Integrated |
| Expansion Interface | |
| Fire Alarm Interface (FAI) | Included only in the version with FAI |
| Power input | 12 or 24 V DC, 12 A (max current) |
| Power output | 12 or 24 V DC, 3.0 A per output (resistive) |
| Fuse rating | ATM 3 A per output |
| General | |
| Compatible products | AXIS A1810-B Network Door Controller, AXIS TA1101-B Wiegand to OSDP Converter |
| Casing | Steel |
| Color | White NCS S 1002-B |
| Cable entry | Top, sides and bottom |
| Connectors | Power (AC input, DC output), FlexIO, Fault output, Battery, FAI input |
| Detection types | AC fault, system fault, cabinet tamper, fire alarm activation |
| LED indicators | FAI, GND FLT, AC FLT, SYS FLT, AC ON |
| Operating temperature | 0 to 49 °C (32 to 120 °F) |
| Operating humidity | 93% at 32 °C (90 °F) |
| Storage temperature | -30 to 70 °C (-22 to 158 °F) |
| Weight | 120 V AC: 13.8 kg (30.5 lb); 230 V AC: 14.3 kg (31.5 lb); 120 V AC with FAI: 14.0 kg (31.0 lb) |
| Documentation | Power unit: FPO250 at LifeSafety Power; Fire Alarm Interface: C8 at LifeSafety Power |
| Approvals | |
| Product markings | BIS, CE, CSA, FCC, NOM, RCM, UKCA, UL, WEEE |
| EMC | EN 55035, EN 55032 Class A, EN 61000-3-2, EN 61000-3-3 |
| Safety | IEC/EN 62368-1:2014, UL 294, ULC S319, ULC 60839-11-1, CSA C22.2 #107.1, CSA C22.2 #205, IS 13252 (Part 1):2010, NOM 001:2018, RCM, SAA, CSFM approved |
| Substance control | RoHS; REACH |
| Box Content | |
| Included items | Enclosure with power, 2 enclosure keys, hardware kit, installation guide, third-party documentation (230 V AC: ferrite and inductor) |
| Shipping (Axis product data) | |
| Weight | 39.73 lb |
| Dimensions (W x D x H) | 26.97 x 22.48 x 8.98 in |