AXIS TA1202 150 W Power Enclosure with FAI, 03337-004
Description
AXIS TA1202 150 W Power Enclosure with Fire Alarm Interface
The AXIS TA1202 Enclosure with Power Unit and FAI is a preassembled, lockable steel enclosure with a 150 W power supply, battery charger and fire alarm interface for AXIS A1710-B four-door systems. The fire alarm interface and its relay board let the lock outputs react to a fire alarm signal. This is the 120 V AC version, and the backup battery is not included.
Key Specifications
| Part number | 03337-004 |
| Type | Enclosure with 150 W power unit and fire alarm interface |
| Compatible with | AXIS A1710-B Network Door Controller, AXIS TA1101-B converters |
| Power supply | 150 W (LifeSafety Power FPO150) |
| Fire alarm interface | Included (LifeSafety Power C4), 120 V AC version |
| AC input | 120/230 V AC +10%/-15%, 50-60 Hz, 2.5 A |
| DC output (12 V jumper) | 11.3-12.0 V, max 20 A (18 A while charging) |
| Battery | Not included; SLA, gel cell or LiFePO4, up to 80 Ah |
| Operating temperature | 0 to 49 °C (32 to 120 °F) |
| Weight | 8.4 kg (18.5 lb) |
| Shipping weight | 20.9 lb |
Full specifications are listed in the Detailed Specifications tab.
Compatible Products
Compatible AXIS products available at Affinitech Store:
Related Products
Related AXIS accessories, available at Affinitech Store:
- AXIS TA1202 150 W 120 V AC Power Enclosure
- AXIS TA1203 250 W Power Enclosure with FAI
- AXIS TA1101-B Wiegand to OSDP Converter
- AXIS TA1201 Wall Mount Enclosure for TA1101-B
Explore More
- See the full Access Control collection
- Browse all Power Supplies at Affinitech Store
- Shop more AXIS products at Affinitech Store
Frequently Asked Questions About AXIS TA1202
What is the difference between this and the standard TA1202?
This version includes the fire alarm interface (FAI) with relay board. The standard AXIS TA1202 (03335-004) does not.
What does the fire alarm interface do?
It adds an FAI input and a switched DC2 output, so power to connected locks can follow a fire alarm signal. LED indicators show FAI, ground fault, AC fault, system fault and AC status.
Which door controller is it designed for?
The AXIS A1710-B Network Door Controller in four-door systems.
Is a backup battery included?
No. It supports sealed lead acid, gel cell or lithium iron phosphate batteries up to 80 Ah.
What mains voltage does it use?
This FAI version is a 120 V AC model.
Detailed Specifications
AXIS TA1202 Specifications
| Specification | Details |
|---|---|
| Product | |
| Model | AXIS TA1202 |
| Part number | 03337-004 |
| Variants | |
| Variant 1 | AXIS TA1202 Enclosure with Power unit, 120 V AC or 230 V AC |
| Variant 2 | AXIS TA1202 Enclosure with Power unit and FAI, 120 V AC (this SKU) |
| Power | |
| Input | 120/230 V AC +10%/-15% at 50-60 Hz, 2.5 A |
| Output, FPO jumper set to 12 V | 11.3-12.0 V, max 20 A (18 A if battery is charging) |
| DC1 output | Continuous |
| DC2 output | Switched on FAI input |
| Protection | Overload and short-circuit protection with auto-restart |
| Battery | |
| Backup battery | Not included |
| Supported types | Sealed Lead Acid (SLA), Gel Cell, or Lithium Iron Phosphate |
| Max battery size | 80 Ah |
| Max charge current | 2 A |
| Fuse rating | ATM 15 A |
| Charger | Built-in microprocessor-controlled smart charger |
| Switchover | Automatic switchover to backup battery with zero transfer time |
| Low battery protection | Integrated low battery cutoff |
| Expansion Interface | |
| Fire Alarm Interface (FAI) | Included in the AXIS TA1202 Enclosure with Power unit and FAI, 120 V AC |
| Power input | 12 or 24 V DC, 12 A (max current) |
| Output | 12 or 24 V DC, 3.0 A per output (resistive) |
| Fuse rating | ATM 3 A per output |
| General | |
| Compatible products | AXIS A1710-B Network Door Controller, AXIS TA1101-B Wiegand to OSDP Converter |
| Casing | Steel |
| Color | White NCS S 1002-B |
| Mounting | Cable entry through top, sides and bottom |
| Connectors | Power: AC input, DC output; FlexIO; Fault output; Battery; FAI input |
| Detection | AC fault, system fault, cabinet tamper, fire alarm activation |
| LED indicators | FAI, GND FLT, AC FLT, SYS FLT, AC ON |
| Operating temperature | 0 to 49 °C (32 to 120 °F) |
| Operating humidity | 93% at 32 °C (90 °F) |
| Storage temperature | -30 to 70 °C (-22 to 158 °F) |
| Weight | 120 V AC with FAI: 8.4 kg (18.5 lb) |
| Documentation | Power unit: FPO150 at LifeSafety Power; Fire Alarm Interface: C4 at LifeSafety Power |
| Approvals | |
| Product markings | BIS, CE, CSA, FCC, NOM, RCM, UKCA, UL, WEEE |
| EMC | EN 55035, EN 55032 Class A, EN 61000-3-2, EN 61000-3-3 |
| Safety | IEC/EN 62368-1:2014, UL 294, ULC S319, ULC 60839-11-1, CSA C22.2 #107.1, CSA C22.2 #205, IS 13252 (Part 1):2010, NOM 001:2018, RCM, SAA, CSFM approved |
| Substance control | RoHS; REACH |
| Box Content | |
| Included items | Enclosure with power and FAI, 2 enclosure keys, hardware kit, installation guide, third-party documentation |
| Shipping (Axis product data) | |
| Weight | 20.9 lb |
| Dimensions (W x D x H) | 17.99 x 22.48 x 15.24 in |