AXIS A1610 2-Door Network Door Controller, 02653-001
Description
AXIS A1610 Network Door Controller – 2 Doors, 4 Readers, PoE+ Powered
The AXIS A1610 is an edge-based network door controller that runs two doors from a single PoE+ cable, with four OSDP reader connections and two Form C relays that power the locks directly. It keeps up to 250,000 credentials and 250,000 events on board, so doors keep working even when the network is down, and its aluminum casing operates from -40 °C to 55 °C. Axis Edge Vault protects its identity and keys, making it a solid choice for schools, offices and multi-tenant buildings that want scalable, IP-based access control.
Key Specifications
| Doors supported | 1-2 wired doors, or 1 wired door plus a wireless lock gateway |
| Readers supported | Up to 4 OSDP or 2 Wiegand; up to 16 AXIS A4612 Bluetooth readers |
| Reader security | OSDP Secure Channel, OSDP Secure Profile verified |
| Lock relays | 2 relays NO/NC, max 2 A at 30 V DC |
| Inputs/outputs | 6 configurable auxiliary/external I/Os plus supervised door and reader I/O |
| Power input | PoE IEEE 802.3at Type 2 Class 4, or 10.5-28 V DC |
| Lock power output | 2x 12/24 V DC (with PoE+: max 900 mA at 12 V in total) |
| Local storage | Up to 250,000 credentials and 250,000 events |
| Elevator control | Up to 16 floors with AXIS A9910 |
| Operating temperature | -40 °C to 55 °C (conditional max 70 °C) |
| Casing / mounting | Aluminum; wall or DIN rail mount; plenum rated |
Full specifications are listed in the Detailed Specifications tab.
Why Choose the AXIS A1610?
- Controls two doors with four reader connections from one controller
- One PoE+ cable powers the controller, the readers and the locks
- Edge intelligence keeps doors working if the network goes down
- Stores up to 250,000 credentials and 250,000 events locally
- OSDP Secure Channel and OSDP Secure Profile verified
- Axis Edge Vault with Axis device ID and CC EAL6+ secure keystore
- Wide -40 °C to 55 °C operating range and plenum rating
- Six configurable auxiliary I/O ports for sensors and alarms
Two Doors From One PoE+ Cable
Two Form C relays (NO/NC, max 2 A at 30 V DC) and two jumper-selectable 12/24 V DC lock outputs let the AXIS A1610 power both locks on board. With PoE+ it supplies up to 900 mA at 12 V DC to the locks in total; with a 10.5-28 V DC supply that rises to 1800 mA at 12 V DC. A 12 V DC battery backup input is also provided.
Flexible Readers and Credentials
Connect up to four OSDP readers or two Wiegand readers, or up to 16 AXIS A4612 Network Bluetooth Readers. Supported credentials include cards and PIN codes, dynamic QR codes for visitor access and license plate recognition for vehicle access. Up to 16 ASSA ABLOY Aperio wireless locks can be integrated through the AH30 Communication Hub.
I/O, Alarms and Elevator Control
Six configurable auxiliary and external I/O ports connect glass-break, intrusion and emergency sensors or other security systems, and supervised inputs with programmable end-of-line resistors monitor door position sensors and REX buttons. Paired with the AXIS A9910 I/O Relay Expansion Module, the A1610 supports elevator control for up to 16 floors.
Built-In Cybersecurity
Axis Edge Vault protects the Axis device ID and stores cryptographic keys, such as the OSDP Secure Channel key, in a CC EAL6+ certified secure keystore. Signed firmware, secure boot, HTTPS, IEEE 802.1X network access control and brute force delay protection round out the device security, and tamper detection covers cover removal, reader tamper, tilting and vibration.
Installation
The AXIS A1610 mounts on a wall or a DIN rail, and its plenum rating lets it go above drop ceilings without an extra installation cabinet. Detachable, color-coded terminal blocks speed up wiring, and the controller ships with mating connectors, a grounding kit and cable ties. Need to install it in your own cabinet? The barebone AXIS A1610-B is sold without a top cover.
Typical Applications
- Two-door vestibules and main entrances
- Office suites, server rooms and secure storage
- Visitor entrances using dynamic QR codes
- Vehicle gates with license plate recognition
- Elevator floor access control with AXIS A9910
- Plenum ceilings and unheated spaces
Compatible Accessories
Compatible accessories for the AXIS A1610, available at Affinitech Store:
- AXIS A4610 Network Reader
- AXIS A4611 Network Reader with Keypad
- AXIS A4612 Network Bluetooth Reader
- AXIS A4030-E Reader
- AXIS A4130-E Reader
- AXIS A4131-E Reader with Keypad
- AXIS TA4711 Access Card (100-pack)
- AXIS TA4712 Key Fob (50-pack)
- AXIS A9910 I/O Relay Expansion Module
- AXIS TA1101-B Wiegand to OSDP Converter
- AXIS TA1802 Top Cover (spare)
- AXIS TA1901 DIN Rail Clip (10-pack)
- AXIS T98A15-VE Surveillance Cabinet
- AXIS TQ1808-VE Surveillance Cabinet
- AXIS 30 W Midspan
- AXIS 30 W Midspan AC/DC
- AXIS T8006 PS12 Power Supply
- AXIS T8007 PS24 Power Supply
- AXIS I/O Indication LED (4-pack)
Compare AXIS Network Door Controllers
| Model | Doors / readers | Type | Best for |
|---|---|---|---|
| AXIS A1210 | 1 door; 2 OSDP or 1 Wiegand reader | Compact PoE door controller | Single doors, plenum spaces |
| AXIS A1210-B | 1 door | Barebone A1210, stackable | Multi-door builds in existing cabinets |
| AXIS A1214 | Up to 4 doors | Kit: four A1210-B in an AXIS TQ1808-VE cabinet | Ready-to-install multi-door sites |
| AXIS A1610 (this controller) | 2 doors; 4 OSDP or 2 Wiegand readers | Advanced PoE+ door controller with top cover | Paired entrances, elevators, harsh spaces |
| AXIS A1610-B | 2 doors; 4 reader connections | Barebone A1610, no top cover | Installs in Axis or third-party cabinets |
| AXIS A1710-B | Up to 4 doors; 8 OSDP readers, 8 locks | Multi-door controller with onboard lock power | Larger buildings with many doors |
| AXIS A1810-B | Up to 8 doors; 16 OSDP readers, 16 locks | Multi-door controller with onboard lock power | Central controller rooms, large sites |
| AXIS A1711 | Up to 4 doors | Kit: A1710-B in an AXIS TA1202 150 W power enclosure (FAI version available) | Fast 4-door deployments |
| AXIS A1811 | Up to 8 doors | Kit: A1810-B in an AXIS TA1203 250 W power enclosure (FAI version available) | Fast 8-door deployments |
Installing in your own cabinet? See the barebone AXIS A1610-B (02654-001), sold without a top cover.
Explore More
- Browse all Network Door Controllers at Affinitech Store
- Shop Access Control Readers at Affinitech Store
- See the full Access Control collection
- More from AXIS
Frequently Asked Questions About AXIS A1610
How many doors does the AXIS A1610 control?
One or two wired doors, or one wired door together with a single wireless lock gateway per controller.
How many readers can I connect?
Up to four OSDP readers or two Wiegand readers, or up to 16 AXIS A4612 Network Bluetooth Readers.
Does it support OSDP Secure Channel?
Yes. OSDP Secure Channel is supported and the A1610 is OSDP Secure Profile verified.
Can it power the door locks?
Yes. It has two 12/24 V DC lock outputs and two Form C relays. With PoE+ the lock outputs supply up to 900 mA at 12 V DC or 410 mA at 24 V DC in total; with DC input, up to 1800 mA at 12 V DC or 750 mA at 24 V DC.
How is the AXIS A1610 powered?
By Power over Ethernet IEEE 802.3at Type 2 Class 4, or by 10.5-28 V DC (max 36 W). A 12 V DC backup input is also provided.
Does it keep working if the network goes down?
Yes. The controller handles door access tasks on the edge and stores up to 250,000 credentials and 250,000 events locally.
What credentials does it support?
Cards, key fobs and PIN codes, plus dynamic QR codes for visitors and license plate recognition for vehicles, depending on the access management software.
Can it control elevators?
Yes. With the AXIS A9910 I/O Relay Expansion Module it supports elevator control for up to 16 floors.
What is the operating temperature range?
-40 °C to 55 °C (-40 °F to 131 °F), with a conditional maximum of 70 °C (158 °F). For UL 294 installations the range is 0 °C to 55 °C.
How is it mounted?
On a wall or a DIN rail. It is plenum rated, so it can be installed in plenum spaces without an extra cabinet.
What is the difference between the A1610 and A1610-B?
The A1610-B is the barebone version of the same two-door controller, sold without a top cover for installation in an Axis or third-party cabinet.
What warranty does it have?
A 5-year Axis warranty.
Detailed Specifications
AXIS A1610 Specifications
| Specification | Details |
|---|---|
| Product | |
| Product | AXIS A1610 Network Door Controller |
| Type | Door controller |
| System Integration | |
| Readers | Up to 4x OSDP readers, or 2x Wiegand readers; up to 16x AXIS A4612 Network Bluetooth Reader; OSDP Secure Channel supported, OSDP Secure Profile verified |
| Doors | 1-2 wired doors or 1 wired door together with a single wireless lock gateway per controller; support for elevator control for 16 floors with AXIS A9910; support for integrating up to 16x ASSA ABLOY Aperio using the AH30 Communication Hub |
| Credentials | Third-party access management software depending on server capacity; up to 250,000 credentials stored locally |
| Event buffer | Qualified for up to 250,000 events stored locally |
| Power | |
| Power in | 10.5-28 V DC, max 36 W (max 2.4 A at 10.5 V, max 0.9 A at 28 V), or Power over Ethernet (PoE) IEEE 802.3at, Type 2 Class 4 |
| Backup | 12 V DC |
| Power out lock | 2x 12/24 V DC. With PoE+: max 900 mA at 12 V DC, max 410 mA at 24 V DC in total. With DC in: max 1800 mA at 12 V DC, max 750 mA at 24 V DC in total |
| Power out reader | 2x 12 V DC, max 500 mA in total |
| Auxiliary DC output | 1x 12 V DC output, max 200 mA |
| Total power budget for peripheral devices | 2100 mA at 12 V if powered by DC; 1300 mA at 12 V if powered by PoE Class 4 |
| Hardware | |
| Memory | 512 MB RAM, 2048 MB Flash |
| Security | Password protection, IP address filtering, HTTPS encryption, IEEE 802.1X (EAP-TLS) network access control, digest authentication, user access log, centralized certificate management, brute force delay protection, signed firmware, secure boot; Axis Edge Vault with Axis device ID, secure keystore (CC EAL6+ certified hardware protection of cryptographic operations, certificates and keys) |
| Network protocols | IPv4, IPv6 USGv6, ICMPv4/ICMPv6, HTTP, HTTPS, HTTP/2, TLS, QoS Layer 3 DiffServ, SFTP, CIFS/SMB, SMTP, mDNS (Bonjour), UPnP, SNMP v1/v2c/v3 (MIB-II), DNS/DNSv6, DDNS, NTP, NTS, RTSP, RTCP, RTP, SRTP, TCP, UDP, IGMPv1/v2/v3, DHCPv4/v6, ARP, SSH, NTCIP, SIP, LLDP, CDP, MQTT v3.1.1, Syslog, Link-Local address (ZeroConf) |
| Events (tamper detection) | Removal of unit cover/tamper front; reader tamper; tilting, vibration |
| Connectors | |
| Ethernet | RJ45 10BASE-T/100BASE-TX PoE |
| Terminal blocks | DC power, 14 inputs/outputs, RS485/Wiegand, relay, battery; detachable and color-coded connectors for ease of installation |
| Reader I/O interface | Power output: 2x 12 V DC, max 500 mA; 2x2 configurable supervised inputs/outputs (digital input: 0 to max 30 V DC; digital output: 0 to max 30 V DC, open drain max 100 mA); Data: OSDP/RS485 half duplex, Wiegand |
| Door I/O interface | Power output: 12/24 V DC, jumper configurable; output relay: 2x relay NO/NC, max 2 A at 30 V DC, resistive; 2x2 supervised inputs for door monitors and REX (digital input: 0 to max 30 V DC) |
| Auxiliary I/O interface | DC output: 1x 12 V DC output, max 200 mA; 4x configurable inputs/outputs (digital input: 0 to max 30 V DC; digital output: 0 to max 30 V DC, open drain max 100 mA) |
| External I/O interface | 2x configurable inputs/outputs for auxiliary equipment (digital input: 0 to max 30 V DC; digital output: 0 to max 30 V DC, open drain max 100 mA) |
| Supervised input | Configurable input for reader interface, door REX input, door position sensor input and AUX; programmable end-of-line resistors, 1 K, 2.2 K, 4.7 K and 10 K, 1%, 1/4 watt standard |
| Wire size for connectors | CSA: AWG 28-16, CUL/UL: AWG 30-14 |
| Cable Requirements | |
| DC power and relay wire | AWG 18-16 |
| Ethernet and PoE | STP CAT 5e or higher |
| Reader data (RS485) | 1 twisted pair with shield, qualified for up to 1000 m (3281 ft) |
| Reader data (Wiegand) | Qualified for up to 150 m (500 ft) |
| Reader powered by controller (RS485) | AWG 20-16, qualified for up to 200 m (656 ft) |
| Reader powered by controller (Wiegand) | AWG 20-16, qualified for up to 150 m (500 ft) |
| I/Os as inputs | Qualified for up to 200 m (656 ft) |
| General | |
| Casing | Aluminum |
| Color | White NCS S 1002-B |
| Sustainability | PVC free |
| Operating conditions | -40 °C to 55 °C (-40 °F to 131 °F); conditional maximum temperature: 70 °C (158 °F); UL 294: 0 °C to 55 °C (32 °F to 131 °F); humidity 20-85% RH (non-condensing) |
| Storage conditions | -40 °C to 55 °C (-40 °F to 131 °F) |
| Mounting | Wall mount; DIN rail mount |
| Languages | English, German, French, Spanish, Italian, Russian, Simplified Chinese, Japanese, Korean, Portuguese, Polish, Traditional Chinese |
| Approvals | |
| EMC | EN 55032 Class A, EN 50130-4, EN 61000-3-2, EN 61000-3-3, EN 55035, EN 61000-6-1, EN 61000-6-2, FCC Part 15 Subpart B Class A, ICES-3(A)/NMB-3(A), VCCI Class A, RCM AS/NZS CISPR 32 Class A, KS C 9832 Class A, KS C 9835 |
| Safety | IEC/EN/UL 62368-1 ed. 3, CAN/CSA C22.2 No. 62368-1 ed. 3, UL 294 |
| Environment | EN 50581 |
| Dimensions and Weight | |
| Dimensions | 175 x 175 x 60 mm (6.9 x 6.9 x 2.4 in) |
| Weight | 1.2 kg (2.6 lb) |
| Box Content | |
| Included accessories | Installation guide, mating connectors (mounted), grounding kit, cable ties |
| Optional Accessories | |
| Optional accessories | AXIS A9910 I/O Relay Expansion Module, AXIS TA4711 Access Card, AXIS TA4712 Key Fob, AXIS TA1802 Top Cover, AXIS TA1901 DIN Rail Clip, AXIS TA1902 Access Control Connector Kit, AXIS T98A15-VE Surveillance Cabinet, AXIS 30 W Midspan, AXIS 30 W Midspan AC/DC, AXIS T8006 PS12 |
| Warranty | |
| Warranty | 5-year warranty |